[Report 1948] / Medical Officer of Health, Bexhill U.D.C. Borough.
- Bexhill (England). Urban District Council.
- Date:
- 1948
Licence: Attribution 4.0 International (CC BY 4.0)
Credit: [Report 1948] / Medical Officer of Health, Bexhill U.D.C. Borough. Source: Wellcome Collection.
46/52 page 44
![TABLE 20 Defective drains . . . . . . . . . . . . . . 56 Choked drains . . . . . . . . . . . . . . . . 26 Manholes repaired . . . . . . . . . . . . . . 9 Choked gullies . . . . . . . . . . . . . . . . i Choked street gullies . . . . . . . . . . . . • • \ 5 Installation of septic tanks . . . . . . . . . . . . 30 Defective waste pipes . . . . . . . . . . . . . . 26 Defective soil pipes . . . . . . . . . . . . . . 24 Defective or overflowing cesspools . . . . . . . . . . 5 Defective w.c. pans . . . . . . . . . . . . . . 25 Defective flushing cisterns . . . . . . . . . . . . 21 Defective urinals . . . . . . . . . . . . . . 2 Absence of flushing cisterns to water closets . . . . . . 2 Lavatory basins fixed . . . . . . . . . . . . . . 28 New baths fixed . . . . . . . . . . . . . . 2 Insanitary and defective sinks replaced . . . . . . . . 9 Defective yard paving. . . . . . . . . . . . . . 13 Defective yard division walls . . . . . . . . . . i Defective roofs . . . . . . . . .... . . 71 Defective and dangerous chimney stacks . . . . . . . . ii Defective eaves, gutters . . . . . . . . . . .. 27 Defective downspouts . . . . . . . . .. .. 3 Defective pointing . . . . . . . . . . . . .. 14 Defective window sash frames and cords . . . . . . . . 43 Defective floors . . . . . . . . . . . . . . 51 Defective plaster of walls and ceilings . . . . . . . . 112 Defective internal walls . . . . . . . . . . . . 13 Defective external walls . . . . . . . . . . . . 21 Wahs requiring cleansing . . . . . . . . . . . . 5 Defective ceilings . . . . . . . . . . . . . . 22 Defective fireplaces and grates . . . . . . . . . . 41 Defective washboilers . . . . . . . . . . . . . . 5 Defective doors, cupboards, etc. . . . . . . . . . . 12 Defective water pipes and fittings . . . . . . . . . . 2 Defective chimney flues . . . . . . . . . . . . 12 Insufficient ventilation of rooms . . . . . . . . . . i Absence of ventilated food store . . . . . . . . . . i Insufficient water supply . . . . . . , . . . . . 2 f/alvanised dustbins ])rovided . . . . . . . . . . 36 Accumulation of manure and refuse . . . . . . 8 ^ Keeping of animals . . . . . . . . . . . . . . 6 hiltliy condition of j)remises . . . . . . . . . . . • 2 Vei min . . . . . . . . . . . . . . . . . . 2 Ditches requiring cleansing . . . . . . . . . . . . i Miscellaneous . . . . . . . . . . . . . . . . 30 711](https://iiif.wellcomecollection.org/image/b28921665_0046.jp2/full/800%2C/0/default.jpg)